影像学检查呈现结果
|
动脉瘤个数
|
3D-CTA
|
3D-DSA
|
χ2值
|
P值
|
瘤颈宽度
|
38
|
30(78.95)
|
37(97.37)
|
6.176
|
0.013
|
瘤颈与载瘤动脉关系
|
38
|
29(76.32)
|
36(94.74)
|
5.208
|
0.022
|
瘤颈形态
|
38
|
31(81.58)
|
37(97.37)
|
5.029
|
0.025
|
[1] FINGERLIN T J,RYCHEN J,ROETHLISBERGER M,et al.Long-term aneurysm recurrence and de novo aneurysm formation after surgical treatment of unruptured intracranial aneurysms:a cohort study and systematic review[J].Neurol Res,2020,42(4):338-345.DOI:10.1080/01616412.2020.1726587.
[2] DISSAUX B,OGNARD J,CHEDDAD EL AOUNI M,et al.Volume variation may be a relevant metric in the study of aneurysm pulsatility:a study using ECG-gated 4D-CTA (PULSAN)[J].J Neurointerv Surg,2019 Nov 7.pii:neurintsurg-2019-015336.DOI:10.1136/neurintsurg-2019-015336.
[3] KORJA M,KIVISAARI R,REZAI JAHROMI B,et al.Size and location of ruptured intracranial aneurysms:consecutive series of 1993 hospital-admitted patients[J].J Neurosurg,2017,127(4):748-753.DOI:10.3171/2016.9.JNS161085.
[4] BOUILLOT P,BRINA O,CHNAFA C,et al.Robust cerebrovascular blood velocity and flow rate estimation from 4D-CTA[J].Med Phys,2019,46(5):2126-2136.DOI:10.1002/mp.13454.
[5] CHEN G,XU M,MA L,et al.Therapeutic evaluation of a patient with ruptured intracranial aneurysm without subarachnoid hemorrhage by CT imaging:a case report[J].BMC Neurol,2018 Nov 29;18(1):197.DOI:10.1186/s12883-018-1197-y.
[6] HADI M,MAXWELL A W P,HIRSCH J A,et al.Clinico-radiologic factors in paraclinoid aneurysms associated with aneurysm rupture:A CTA study[J].Clin Imaging,2019,53:225-229.DOI:10.1016/j.clinimag.2018.10.016.Epub 2018 Oct 22.
[7] MORAIS R,MINE B,BRUYERE P J,et al,Endovascular treatment of intracranial aneurysms with the p64 flow diverter stent:midterm results in 35 patients with 41 intracranialaneurysms[J].Meuroradiology,2017,59(3):263-269.DOI:10.1007/s00234-017-1786-2.
[8] DUARTE CONDE M P,DE KORTE A M,MEIJER F J A,et al.Subtraction CTA:An Alternative Imaging Option for the Follow-Up of Flow-Diverter-Treated Aneurysms?[J].AJNR Am J Neuroradiol,2018,39(11):2051-2056.DOI:10.3174/ajnr.A5817.
[9] MARBACHER S,MENDELOWITSCH I,GRTER BE,et al.Comparison of 3D intraoperative digital subtraction angiography and intraoperative indocyanine green video angiography during intracranial aneurysm surgery[J].J Neurosurg,2018,131(1):64-71.DOI:10.3171/2018.1.JNS172253.
[10] WANG L,YE X,HAO Q,et al.Three-dimensional intracranial middle cerebral artery aneurysm models for aneurysm surgery and training[J].J Clin Neurosci,2018,50:77-82.DOI:10.1016/j.jocn.2018.01.074.
[11] SINGH R,GUPTA V,AHUJA C,et al.Role of time-resolved-CTA in intracranial arteriovenous malformation evaluation at 128-slice CT in comparison with digital subtraction angiography[J].Neuroradiol J,2018,31(3):235-243.DOI:10.1177/1971400917744403.
[12] CARR S B,IMBARRATO G,BREEZE R E,et al..Clip ligation for ruptured intracranial aneurysm in a child with Loeys-Dietz syndrome:case report[J].J Neurosurg Pediatr,2018,21(4):375-379.DOI:10.3171/2017.10.PEDS17193.
[13] ZHANG H,FENG L.Coarctation of the Aorta Complicated with Intracranial Aneurysm:A Case Report and Literature Review[J].World Neurosurg,2018,112:25-30.DOI:10.1016/j.wneu.2018.01.011.
[14] ZHOU L Q,LOU M W,CHEN G C,et al.Value of 640-slice 3D CT angiography plus 3D printing for improving surgeries for intracranial aneurysms[J].Nan Fang Yi Ke Da Xue Xue Bao,2017,37(9):1222-1227.
[15] DAHBOUR L,MANSOUR T R,ALNEMARI A,et al.Diagnostic Work-Up of a Giant Calcified Intracranial Aneurysm:Comparing 4D-CTA and Cerebral Angiogram Findings[J].Cureus,2017,9(6):e1367.DOI:10.7759/cureus.1367.
[16] MINE B,TANCREDI I,ALJISHI A,et al.Follow-up of intracranial aneurysms treated by a WEB flow disrupter:a comparative study of DAS and contrast-enhanced MR angiography[J].J Neurointery Sury,2016,8(6):615-620.DOI:10.1136/neur intsurg-2015-011644.
[17] BIER G,BONGERS M N,HEMPEL J M,et al.Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling-improved image quality by iterative metalartifact reduction[J].Neuroradiology,2017,59(7):649-654.DOI:10.1007/s00234-017-1855-6.
[18] BURKHARDT J K,FIERSTRA J,ESPOSITO G,et al.Rapid Documented Growth of Aneurysm Bleb Led to Rupture of an Incidental Intracranial Anterior Communicating Artery Aneurysm[J].J Neurol Surg A Cent Eur Neurosurg,2017,78(5):521-524.DOI:10.1055/s-0037-1598053.
[19] SABOUR S,LI Z Y.Reproducibility of image-based computational models of intracranial aneurysm;methodological issue[J].Biomed Eng Online,2016,15:109.DOI:10.1186/s12938-016-0223-9.